These are custom direct-diode laser systems constructed using the casing of a Coherent CUBE laser head. In each one, the control electronics from Coherent have been removed along with the original laser diode. The new laser diode is driven by an ACS1500SE mounted in place of the Coherent control electronics, and the driver board inputs have been connected to a DB-9 connector installed on the back of the unit in place of the original DE-15 connector. Each build is basically the same project repeated with a different diode, and they differ mainly in wavelength, output power, and whether the TEC and temperature sensor in the casing are being used.
The ACS1500SE laser driver is capable of both boosting and bucking the power to deliver what is needed to the laser diode. It accepts an input range of 2.9-12VDC and can output up to 1500mA to the laser diode. The front of each device has a manually operated shutter that can be closed to protect the glass lens when not in use or block laser output.
We have built four of these so far:
- Blue 450nm 80mW - NT-LS-DB80-C (Osram PLT5 450B, TEC and temperature sensor connected)
- Cyan 488nm 55mW - NT-LS-DC55-C (Sharp GH04850B2G, TEC and temperature sensor not connected)
- Green 515nm 35mW - NT-LS-DG35-C (Sharp GH05130C2GL, TEC and temperature sensor connected)
- Mint Green 505nm 35mW - NT-LS-DM35-C (Sharp GH05035A2G, third-party diode mount, no TEC or temperature sensor)
Custom Blue 450nm 80mW Direct Diode Laser System [NT-LS-DB80-C]
The NT-LS-DB80-C uses the casing and diode host of a Coherent CUBE laser head. The diode used is an Osram PLT5 450B operating at a wavelength of 450nm and up to ~100mW of output power. The driver board input connections and the thermal management system connections of the Coherent CUBE casing have all been connected to the DB-9 connector on the back of the unit. The temperature of the laser diode can be monitored and controlled with the TEC and temperature sensor built into the host in which the laser diode is mounted.
The original laser diode for this device was sourced directly from a Blu-Ray drive. There were some issues with the diode from the Blu-Ray drive and it eventually stopped working. A replacement diode was purchased and installed into the host within the CUBE case. This diode in particular has a nominal current of around 165mA and a maximum rated current of 275mA. The laser driver is set to output around 150mA to the diode, well under the rated current. This is done to preserve the life of the diode and keep the output power manageable. As currently configured, this laser outputs about 40mW but has not been measured using a precise instrument. During testing, the laser diode was run much closer to its rated maximum output power of ~100mW. Running at this power level, with a properly focused lens, made the laser powerful enough to burn a technician's hand slightly when it was held directly in front of the beam.
The laser diode is mounted behind an adjustable lens.
The beam is very bright and a nice deep blue color. For a custom laser, its performance is exceptional. There is a noticeable difference from the purple/violet beam of the Blu-Ray diode.
Custom Cyan 488nm 55mW Direct Diode Laser System [NT-LS-DC55-C]
The NT-LS-DC55-C uses the casing and diode host of a Coherent CUBE laser head. The diode used is a Sharp GH04850B2G operating at a wavelength of 488nm and up to ~55mW of output power. While there is a temperature sensor and TEC installed in this casing, it is not currently connected or in use in this particular laser system.
This diode in particular has a nominal current of around 105mA and a maximum rated current of 135mA. The laser driver is set to output around 100mA to the diode, well under the rated current. This is done to preserve the life of the diode and keep the output power manageable. As currently configured, this laser outputs about 20mW but has not been measured using a precise instrument.
The laser diode is mounted behind an adjustable lens.
The beam is cyan in color but does show up differently on camera than in person. This system is quite interesting as 488nm is a relatively uncommon laser wavelength. A Spectra-Physics unit of similar power level and the same wavelength has sold used on eBay for over $1,000! The entire cost of this unit was around $120. It may not be quite as reliable as the Spectra-Physics model, but for a custom laser, its performance is exceptional.
Custom Green 515nm 35mW Direct Diode Laser System [NT-LS-DG35-C]
The NT-LS-DG35-C uses the casing and diode host of a Coherent CUBE laser head. The diode used is a Sharp GH05130C2GL operating at a wavelength of 515nm and up to ~35mW of output power. The driver board input connections and the thermal management system connections of the Coherent CUBE casing have all been connected to the DB-9 connector on the back of the unit. The temperature of the laser diode can be monitored and controlled with the TEC and temperature sensor built into the host in which the laser diode is mounted.
This diode in particular has a nominal current of around 90mA and a maximum rated current of 135mA. The laser driver is set to output around 70mA to the diode, well under the rated current. This is done to preserve the life of the diode and keep the output power manageable. As currently configured, this laser outputs about 20mW but has not been measured using a precise instrument. The laser diode is mounted behind an adjustable lens.
The beam is green in color when viewed on camera, but resembles a wintergreen color when viewed in person. Notably, there is a significant amount of scattered light around the beam. This could be due to a dirty lens or possibly an issue with the diode. We are still working on this unit and hope to get this corrected.
Custom Mint Green 505nm 35mW Direct Diode Laser System [NT-LS-DM35-C]
The NT-LS-DM35-C is capable of outputting 35mW of 505nm laser light. Unlike the other builds, it is built using a modified Coherent CUBE enclosure and a third-party diode mounting block and lens. The diode used is a Sharp GH05035A2G, operating at a wavelength of 505nm and up to 35mW of output power. There is no temperature sensor or TEC in this laser system.
The driver in this unit has been configured to output 125mA to the laser diode, which is its normal operating current.
There is a small, cheap collimating lens installed in the threaded opening in the diode mounting block. This will eventually be replaced by a higher quality lens. The light output produced by this unit is acceptable for a custom laser assembled with mostly spare parts!
The beam resembles a pale green or "mint" color, but does show up differently on camera than in person. Comparing this 505nm laser to a 488nm diode laser of similar output power clearly shows the color difference. The 488nm appears more pale blue on camera. Both are excellent low-power wavelengths for experiments and projects!