Unconventional uses for a Nissan Altima instrument cluster (audio visualizer and CPU usage display)

If you haven't already, check out the writeup for the Ford Crown Victoria instrument cluster as it explains some of the basics of how the instrument cluster operates and communicates with the vehicle. The goal with this project was to work with a more modern instrument cluster to enable more control through the CANBUS. The Nissan Altima instrument cluster (technical documentation refers to it as the combination meter) design dates from 2008 and was pulled from a 2008 Altima, which is a bit newer than the Crown Vic cluster which dates back to the mid-2000s. While not all functions of the Altima cluster are controllable via CANBUS, most are, and more importantly the speedometer and tachometer are. Luckily there are no proprietary protocols, so the remaining functions such as the fuel gauge and charging system indicator are controlled in an analog manner via wires on the main connector. Those can be controlled with an Arduino or something similar if desired.

Nissan Altima instrument cluster

CANBUS commands and IDs were derived using a similar method to the Crown Vic cluster but in a slightly more optimized manner. Fuzzing/random data was sent but at a slower speed and a log was kept. When the cluster responded, the script was stopped and another script was used to step through the log history until the desired result was displayed on the cluster. The ID and command were then recorded. Some example commands and IDs are listed below. Most notably with the Nissan Altima instrument cluster was the fact that the cluster itself was sending data under 4 different CANBUS device IDs instead of just 1. Additionally, certain functions on the cluster are controlled by separate CANBUS IDs despite likely originating from the same module. For example, the tachometer responds to commands sent by the CANBUS device ID of 180, but the service engine soon MIL responds to ID 551, and the oil pressure MIL responds to ID 358. All of these indicators likely originate from the ECU but use different IDs for some reason. This could be due to the increased complexity of newer vehicles or just manufacturer choice, it is not completely clear why this is the case. In the case of the Crown Vic instrument cluster, each module (cluster included) had only 1 associated CANBUS device ID.

Example CANBUS device IDs, commands, and functions
ID DATA MODULE FUNCTION
280 METER
2DE METER
5C5 METER
355 METER
180 FF00000000000000 ECU ENGINE RPM (00-FF)
284 FFFFFFFF70FFFFFF ECU VEHICLE SPEED (00-70 visible)
351 0000000000400000 KEY KEY MIL
351 0000000000D00000 KEY RAPID BEEP
354 0000000000000000 ABS CLEARS ABS & BRAKE MIL
354 0000000009000000 ABS ABS MIL ONLY
354 0000000005000000 ABS BRAKE MIL ONLY
354 000000000A000000 ABS ENABLES BRAKE AND ABS MIL
358 0000000000000000 TPMS/ECU CLEARS TPMS MIL
358 0000000080000000 TPMS/ECU TPMS MIL
358 000000A000000000 TPMS/ECU OIL MIL, CLEARS TPMS MIL
551 ECU SES MIL / TEMP / CRUISE
551 AA00000000000000 ECU COOLANT TEMP (50-AA visible)
60D 0000000000000000 LCM/BCM BACKLIGHT ON (LIGHTS OFF)
60D 0060000000000000 LCM/BCM TURN SIGNAL
60D 000B000000000000 LCM/BCM HIGH BEAM IND
60D 0400000000000000 LCM/BCM BACKLIGHT OFF (LIGHTS ON)
60D A000000000000000 LCM/BCM DOOR/TRUNK WARNING
60D 0700003000000000 LCM/BCM CONTINUOUS BEEP

This project was taken a step further as sending arbitrary CANBUS data and watching the indicators flash and gauges move was getting boring. A bash script was written to obtain system information such as CPU and RAM usage as a percentage and CPU temperature. These values are then converted to hexadecimal to be sent over the CANBUS using a specially crafted command the script puts together. Some fine tuning of the gain values may be necessary depending on your system, but the script works well and can be used to have the instrument cluster display Linux system resource usage using the gauges. The tachometer displays CPU usage, the speedometer displays RAM usage, and the coolant temperature gauge displays CPU temperature. A short delay is used to prevent the gauges from shaking too much. Along with the commands to control the tachometer, speedometer, and coolant temperature gauge, additional commands are sent once per second to turn off the warning MILs and enable the backlight to make the cluster text and gauges more visible during operation. A link to the bash script is at the bottom of this page.

Instrument cluster displaying system resource usage

A pinout for the instrument cluster is provided below. This was pulled from the factory service manual for the 2008 Nissan Altima.

Nissan Altima instrument cluster pinout

While working on an unrelated CANBUS project, we decided to bring the Nissan Altima instrument cluster back out and make it do something interesting. Leveraging our past research on this device, we already had the CANBUS device IDs and bitfields that control the various gauges and indicator lamps. With some help from an AI, we created a set of Python scripts that first calibrate the instrument cluster and determine the reactivity of the indicators and gauges. After calibration, an MP3 song file is analyzed by the program and then saved as a beatmap/audio definition file. The Python library librosa is used to analyze and extract details from the song. The same script accepts the MP3 song file and definition to play the audio while transmitting CANBUS frames in sync with the various auditory elements. The result is an instrument cluster that reacts in sync with the music. The gauges and indicators respond uniquely to varying beats and frequencies throughout the song. The speedometer is programmed to be a reflection of the current "energy" of the song, while the tach reacts to the main beat. It's an interesting effect, but still needs some adjustment. The gauges can only move so fast, and will attenuate with fast songs. Also, the indicators will occasionally alias and blink slower if they are driven faster than the internal controller allows. This is mostly compensated for in the Python script, but results in a level of reactivity from the cluster that's good, but not as responsive as we'd prefer. While it's still a work in progress, this was a fun weekend project that demonstrates more unconventional uses for car parts. Check out the video previews below.



The script package can be downloaded at the link below. We do not recommend using this on a real vehicle's CANBUS network. Standalone instrument clusters are preferred as sending arbitrary data to the other vehicle modules could present a safety risk or damage the vehicle. As always, we're open to feedback on this project.