3M Stormscope WX-10A/WX-11 Display and Custom Controller

The 3M Stormscope is an aircraft weather mapping system designed to aid pilots in navigating around storm cells and thunderstorms during flight. The system consists of three main components: a signal processor, an antenna, and a display. The processor is a solid-state device that is installed in the aircraft and connected to power, the remote display, and the antenna. The antenna is mounted externally on the aircraft. The display is mounted in the cockpit, and is the pilot's interface to the system. The display fits in a standard 3-inch octagonal cutout and includes a small CRT display, illumination, and the operational controls. The theory of operation is relatively straightforward: the Stormscope antenna detects the electrical discharge activity resulting from nearby thunderstorms 360° around the aircraft. The processor computes and sorts these detections and displays them on the CRT in a pattern of dots around the aircraft. This allows the pilot to circumnavigate thunderstorms and minimize exposure to turbulence and adverse weather. This page focuses on the display unit as we don't currently have the other two components. The WX-10A and WX-11 Stormscope systems use virtually the same display hardware and connections, so this page applies to both models.

3M Stormscope WX-10A

This is the front of the display, visible to the pilot. The Stormscope display connects to the processor which can be mounted elsewhere in the aircraft, allowing the pilot to customize the position and installation based on their aircraft. The display includes a small CRT and illuminated graticule that helps the pilot understand where the thunderstorms are in relation to the aircraft. In addition to the CRT, several controls are available. The BRT dial adjusts the CRT intensity. The rotary selector on the left is the mode selector switch: OFF, ON, and FWD to focus on the forward 180° of detections. The rotary selector on the right adjusts the range display: 25, 50, 100, or 200 nm. The test button runs an operational self test and can be used before and during flight. The CLR button clears the currently displayed dots from the screen.

3M Stormscope WX-10A

The instrument is a bit over 9 inches long and fits within the standard aircraft cockpit panel 3-inch octagonal opening.

3M Stormscope WX-10A

On the back of the instrument is an information label along with an edge-connector that inserts into a socket on the mounting cage. According to the label, this instrument's part number is 78-8047-0984-4. The outer cover is secured by two Phillips screws (one obscured by a warranty label). In the lower left corner is a grounding post that inserts into a hole in the mounting cage.

3M Stormscope WX-10A

The pin-out for this connector is provided in the 3M Stormscope Installation manual, but is also provided below as it's a bit difficult to read in the photocopied version of the manual.

3M Stormscope WX-10 / WX-10A / WX-11 display connector P7/J7 (Cinch 50-20A-30 or Molex 09-50-6105)
Pin Signal Notes
1TESTTest button
2PWR SW RETURNPower switch return; card edge silkscreen "BAT"
3POWER SWITCHPower switch; card edge silkscreen "PWR"
4FORWARDForward view
5CLEARClear button
6RANGE 2Range switch bit 2
7RANGE 1Range switch bit 1
8LAMP14 V and 5 V systems: ground. 28 V system: to aircraft dimmer
9LAMP CENTER TAP14 V and 5 V systems: to aircraft dimmer. 28 V system: no connection
10LAMPAll systems: ground
A-15 VSupply from processor
B+15 VSupply from processor
CCOM (15 V)Supply common
D+HORIZ DEFLECTIONTwisted pair with pin E
E-HORIZ DEFLECTIONTwisted pair with pin D
F+VERT DEFLECTIONTwisted pair with pin H
H-VERT DEFLECTIONTwisted pair with pin F
JUNBLANKINGShielded
KINHIBITMicrophone inhibit from processor
LINHIBITInhibit line to microphone switch line (single-mic systems). Multi-mic systems need a 1N4448 diode on each mic inhibit line

This is the mounting cage which secures the display to the cockpit panel. As the four corner screws are tightened, it simultaneously pulls the display closer to the cockpit panel and locks the instrument in place. As the instrument is slid into the mounting cage, the edge-connector inserts into the mating connector on the back.

3M Stormscope WX-10A

Removing the two Phillips screws allows the outer casing to be slid away from the inner frame, revealing the components.

3M Stormscope WX-10A

The Stormscope display is very tightly packed inside. It includes a high-quality miniature CRT tube and all the circuitry required to generate the high voltage and drive it.

3M Stormscope WX-10A

This rear view showcases the compact arrangement of four individual circuit boards that drive the CRT tube and distribute the control switch inputs. One board includes an extended section for the edge-connector. A large rubber grommet protects the rear portion of the glass tube.

3M Stormscope WX-10A

This top view shows the tube and two of the boards, along with one of the rotary selector switches. The small anode cap is covered with some tape. We looked up some of the markings and labels on the tube, but were unable to determine its origin. The rotary switches use long metal shafts that extend past the CRT tube to the actual switch body mounted near the circuit boards.

3M Stormscope WX-10A

Here is a side profile view that shows the board arrangement, tube position, and edge-connector.

3M Stormscope WX-10A

This view clearly shows the anode connection and rubber spacer that protects more of the glass tube. The wiring for the illumination runs alongside the tube. The two pushbuttons on the front use metal rods to activate micro switches mounted on the circuit boards behind the tube.

3M Stormscope WX-10A

This is the power converter board (78-8041-7594-7). A TL494CN PWM control chip drives the small pot-core transformer, appropriately sized for the small CRT. This board generates a 550V rail and the +250V deflection rail.

3M Stormscope WX-10A

This is the CRT high voltage / gun board (78-8041-7596-2). It takes the 550V input and steps it up through the stack of disc capacitors and diodes to form a voltage multiplier circuit. Output pads on the rear that go directly to the CRT tube are labeled FOC (focus), CAT (cathode), G1 (grid 1), FIL (filament), UNBLK (unblanking). R209, "CRT BIAS", sets G1's resting cutoff, which is how dark the beam sits with no unblank pulse.

3M Stormscope WX-10A

This is the interface and edge-connector board (78-8041-7598-8). All inputs and outputs route here, and it's mostly just a distribution board. One micro switch is mounted on this board, which is actuated by the front panel button. The brightness rheostat, range selection switch, and power/mode switch connections also route to this board. There is a connection labeled ASTIG (astigmatism) on this board along with a potentiometer in the center that adjusts the astigmatism. The unblanking input also passes through this board.

3M Stormscope WX-10A

This is the deflection amplifier board (78-8041-7600-2). It's an all-discrete design (Q401-Q417) with four RN60D1743F collector loads fed from the +250V rail. This resembles an electrostatic CRT design with four deflection plates. There appears to be no yoke connection, which means the cylinder around the tube is likely just for shielding. There are four potentiometers used to fine-tune the image displayed: VERT GAIN, HORIZ GAIN, HORIZ CENT, and VERT CENT. Also on this board is one of the two micro switches actuated by the front panel buttons.

3M Stormscope WX-10A

We spent a while analyzing the inputs and outputs of this display. The installation manual was quite helpful but didn't tell us everything. It turned out to be mostly straightforward, with one quirk related to the unblanking input. This input must be pulsed at around +15V to unblank the beam. The quirk is that it does not stay unblanked while the input is pulled high; the input must be pulsed regularly to allow an image to be displayed. Other than that, the deflection inputs behave similarly to other electrostatic CRTs. The graticule and illumination inputs were straightforward along with the switches as they all route to the edge-connector. The power/mode selector just shorts the PWR SW and PWR SW RETURN connections, and the FWD position, TST and CLR pushbuttons, and the range switch all short their respective connections to ground based on the position. Make sure you turn up the BRT knob as ours was set to the minimum at first, which will prevent the beam from being displayed at all. With this knowledge, we developed a custom circuit board that drives the Stormscope display and processes the switch inputs. It uses an ESP-32 and simple firmware that can be customized as needed.

3M Stormscope WX-10A

With the firmware and board working, we connected the Stormscope display and used a test pattern to center and adjust the display. The onboard potentiometers make this very straightforward. We then ran some demos on the display, and the result was excellent.

This demo simulates a classic sweeping radar display using random data to create periodic blips on the display.

This demo is a tribute to the Stormscope's original purpose, to display thunderstorm activity in relation to the aircraft's position.

This board is currently under evaluation and testing. It uses a Mean Well split rail DC-DC converter to provide +/-15V DC to the display, a PWM circuit for the illumination, a TL074 operational amplifier to drive CRT deflection inputs, a TC4427A for unblanking, and an ESP-32 to orchestrate everything. We plan to offer this as a product available for purchase from Directed Energy Systems and will publish additional information soon. A link to the Stormscope installation manual is provided below.